1
1

00:00:00,290  -->  00:00:02,220
<v ->Copper cable issues.</v>
2

2

00:00:02,220  -->  00:00:03,370
Now, in this lesson,
3

3

00:00:03,370  -->  00:00:05,750
we're going to discuss the various copper cable issues
4

4

00:00:05,750  -->  00:00:07,030
that you may experience.
5

5

00:00:07,030  -->  00:00:09,130
This includes things like incorrect pinouts,
6

6

00:00:09,130  -->  00:00:11,620
bad ports, opens, and shorts.
7

7

00:00:11,620  -->  00:00:13,700
First, we have incorrect pinouts.
8

8

00:00:13,700  -->  00:00:15,770
If you're testing a twisted pair of network connection,
9

9

00:00:15,770  -->  00:00:17,340
and it isn't working properly,
10

10

00:00:17,340  -->  00:00:19,380
the chances are, your connections pinout
11

11

00:00:19,380  -->  00:00:20,720
is probably incorrect.
12

12

00:00:20,720  -->  00:00:21,810
Now, there are a few places
13

13

00:00:21,810  -->  00:00:23,780
that connections pinout could be incorrect,
14

14

00:00:23,780  -->  00:00:25,960
including the patch panel, the wall jack,
15

15

00:00:25,960  -->  00:00:28,520
or the RJ45 connector itself.
16

16

00:00:28,520  -->  00:00:29,930
When you look at the patch panel,
17

17

00:00:29,930  -->  00:00:31,130
there's usually going to be a sticker
18

18

00:00:31,130  -->  00:00:34,140
near the punch-down block that shows you what wire or pin
19

19

00:00:34,140  -->  00:00:35,980
should be attached to each connection point
20

20

00:00:35,980  -->  00:00:37,400
on that patch panel.
21

21

00:00:37,400  -->  00:00:41,553
By default, most patch panels use a TIA 568B pinout.
22

22

00:00:42,410  -->  00:00:44,560
This means we have pins one through eight
23

23

00:00:44,560  -->  00:00:47,750
being connected as white/orange, orange,
24

24

00:00:47,750  -->  00:00:51,430
white/green, blue, white/blue, green,
25

25

00:00:51,430  -->  00:00:53,570
white/brown and brown.
26

26

00:00:53,570  -->  00:00:55,220
If you're having an issue with the connection
27

27

00:00:55,220  -->  00:00:57,210
and you suspect the pinout is incorrect,
28

28

00:00:57,210  -->  00:00:58,530
you need to visually inspect
29

29

00:00:58,530  -->  00:01:01,130
the back of the patch panel and it's punch-down block
30

30

00:01:01,130  -->  00:01:02,350
to ensure the proper colors
31

31

00:01:02,350  -->  00:01:04,410
are being put in the proper pins.
32

32

00:01:04,410  -->  00:01:06,340
Now, when you're looking at the back of a wall jack,
33

33

00:01:06,340  -->  00:01:08,480
the exact same thing holds true.
34

34

00:01:08,480  -->  00:01:10,350
Instead of being shown as pins one through eight
35

35

00:01:10,350  -->  00:01:13,100
in a horizontal layout like you might see in a patch panel,
36

36

00:01:13,100  -->  00:01:14,720
most wall jacks will usually have
37

37

00:01:14,720  -->  00:01:16,360
four pins on one end of the jack,
38

38

00:01:16,360  -->  00:01:18,080
and four pins on the other.
39

39

00:01:18,080  -->  00:01:20,640
This wall jack is also known as a keystone.
40

40

00:01:20,640  -->  00:01:23,340
And it's clearly going to be labeled as pins one through eight,
41

41

00:01:23,340  -->  00:01:26,210
or visually using color code stickers or markers
42

42

00:01:26,210  -->  00:01:27,980
for each pin's location.
43

43

00:01:27,980  -->  00:01:31,000
Finally, we have our RJ45 connector itself.
44

44

00:01:31,000  -->  00:01:33,550
These plastic connectors are using net copper pins
45

45

00:01:33,550  -->  00:01:37,920
to the inner twisted pair wires of a UTP or STP cable.
46

46

00:01:37,920  -->  00:01:41,640
While an RJ45 is not clearly labeled from pin one to eight,
47

47

00:01:41,640  -->  00:01:44,900
or with the TIA 568B color scheme you need,
48

48

00:01:44,900  -->  00:01:46,710
you can always visually look at the pins
49

49

00:01:46,710  -->  00:01:50,050
and see all eight pins inside the RJ45 connector.
50

50

00:01:50,050  -->  00:01:51,920
When you hold up the RJ45 connector
51

51

00:01:51,920  -->  00:01:54,430
with a small plastic clip facing downward,
52

52

00:01:54,430  -->  00:01:55,680
you can then look at the pins
53

53

00:01:55,680  -->  00:01:57,510
and count them from left to right,
54

54

00:01:57,510  -->  00:01:59,220
numbered from one to eight.
55

55

00:01:59,220  -->  00:02:00,600
Again, this will ensure
56

56

00:02:00,600  -->  00:02:02,040
that your inner twisted pair wires
57

57

00:02:02,040  -->  00:02:03,430
are color coded correctly
58

58

00:02:03,430  -->  00:02:06,760
as white/orange, orange, white/green, blue,
59

59

00:02:06,760  -->  00:02:09,710
white/blue, green, white/brown, brown,
60

60

00:02:09,710  -->  00:02:12,080
when you view it from pin one to pin eight.
61

61

00:02:12,080  -->  00:02:15,040
To test the connection or a cable and verify its pinout,
62

62

00:02:15,040  -->  00:02:18,460
you can also use a cable tester or a wire mapping tool.
63

63

00:02:18,460  -->  00:02:20,050
These tools will test the inner wire
64

64

00:02:20,050  -->  00:02:21,400
from your cable or connection,
65

65

00:02:21,400  -->  00:02:22,930
and ensure they're properly cabled
66

66

00:02:22,930  -->  00:02:24,750
from one end to the other.
67

67

00:02:24,750  -->  00:02:27,360
If the connection is found to be incorrectly pinned out,
68

68

00:02:27,360  -->  00:02:29,730
you can simply disconnect the individual wires,
69

69

00:02:29,730  -->  00:02:32,360
re-strip the twisted pair cable using a wire stripper,
70

70

00:02:32,360  -->  00:02:33,680
and re-punch down the wires
71

71

00:02:33,680  -->  00:02:35,530
into the patch panel or wall jack,
72

72

00:02:35,530  -->  00:02:38,750
or replace the RJ45 connector on the cable
73

73

00:02:38,750  -->  00:02:40,940
until all portions are properly using
74

74

00:02:40,940  -->  00:02:44,270
the TIA 568B wiring standards.
75

75

00:02:44,270  -->  00:02:47,810
Next, we have the issue of bad ports in a copper network.
76

76

00:02:47,810  -->  00:02:50,560
Each network interface card on a workstation or server
77

77

00:02:50,560  -->  00:02:53,240
needs to connect to an ethernet twisted pair network,
78

78

00:02:53,240  -->  00:02:54,840
is going to have an ethernet port,
79

79

00:02:54,840  -->  00:02:58,160
that it's going to use and accept an RJ45 connector into.
80

80

00:02:58,160  -->  00:02:59,770
If you need to test the ethernet port
81

81

00:02:59,770  -->  00:03:01,420
on your network interface card,
82

82

00:03:01,420  -->  00:03:03,250
you're going to need to use a loopback plug,
83

83

00:03:03,250  -->  00:03:04,890
and specialized software.
84

84

00:03:04,890  -->  00:03:06,250
This will let you send out data
85

85

00:03:06,250  -->  00:03:08,420
and have it returned back in the ethernet port,
86

86

00:03:08,420  -->  00:03:10,800
and determine if everything's functioning properly.
87

87

00:03:10,800  -->  00:03:11,660
If it isn't,
88

88

00:03:11,660  -->  00:03:13,980
you need to replace the network interface card.
89

89

00:03:13,980  -->  00:03:15,300
If the network interface card
90

90

00:03:15,300  -->  00:03:16,900
is soldered to your motherboard,
91

91

00:03:16,900  -->  00:03:19,180
you can then add an expansion card instead
92

92

00:03:19,180  -->  00:03:21,970
to replace this broken onboard ethernet port.
93

93

00:03:21,970  -->  00:03:25,010
Now, if you suspect a bad port on a switch or a router,
94

94

00:03:25,010  -->  00:03:26,580
you need to connect a loopback plug
95

95

00:03:26,580  -->  00:03:27,960
to the port on that device
96

96

00:03:27,960  -->  00:03:30,070
and run a test using specialized software,
97

97

00:03:30,070  -->  00:03:32,100
just like you would on a workstation.
98

98

00:03:32,100  -->  00:03:34,480
Now, if the port is found to be faulty or bad,
99

99

00:03:34,480  -->  00:03:36,780
you can then switch out any connections from that port
100

100

00:03:36,780  -->  00:03:39,340
to another available port on the switch or router.
101

101

00:03:39,340  -->  00:03:40,560
In the case of a router,
102

102

00:03:40,560  -->  00:03:42,760
you may also be able to replace the ethernet port
103

103

00:03:42,760  -->  00:03:44,360
by changing out the interface card
104

104

00:03:44,360  -->  00:03:46,380
for the router on that slot.
105

105

00:03:46,380  -->  00:03:48,740
If not, you're going to have to simply move that connection
106

106

00:03:48,740  -->  00:03:50,600
to another available port.
107

107

00:03:50,600  -->  00:03:52,950
Finally, we have opens and shorts.
108

108

00:03:52,950  -->  00:03:55,640
When you conduct a cable test of a twisted pair connection,
109

109

00:03:55,640  -->  00:03:57,690
you may find an open or a short exists
110

110

00:03:57,690  -->  00:03:59,490
on that cable connection.
111

111

00:03:59,490  -->  00:04:02,360
The result of open is going to occur during a cable test,
112

112

00:04:02,360  -->  00:04:04,900
if you have nothing on the other end of the connection,
113

113

00:04:04,900  -->  00:04:07,070
or if there's some kind of a break in the wires
114

114

00:04:07,070  -->  00:04:09,210
between the source and the destination.
115

115

00:04:09,210  -->  00:04:11,320
So, if I'm conducting a test of a cable
116

116

00:04:11,320  -->  00:04:13,280
from a patch panel to the wall jack,
117

117

00:04:13,280  -->  00:04:15,300
over a patch cable into my tester,
118

118

00:04:15,300  -->  00:04:16,640
and it reports as open,
119

119

00:04:16,640  -->  00:04:19,140
that means somewhere in that end-to-end connection,
120

120

00:04:19,140  -->  00:04:20,260
it's either disconnected,
121

121

00:04:20,260  -->  00:04:21,630
or one of those cables
122

122

00:04:21,630  -->  00:04:23,490
has been accidentally cut or broken.
123

123

00:04:23,490  -->  00:04:24,900
At that point, we're going to need
124

124

00:04:24,900  -->  00:04:26,500
to test each piece of the connection
125

125

00:04:26,500  -->  00:04:28,460
to determine where that break exists.
126

126

00:04:28,460  -->  00:04:31,090
For example, I might first test the patch cable.
127

127

00:04:31,090  -->  00:04:32,300
And if that's successful,
128

128

00:04:32,300  -->  00:04:34,370
I know that the problem isn't my patch cable,
129

129

00:04:34,370  -->  00:04:36,690
and instead, I'm going to look at the patch panel connection,
130

130

00:04:36,690  -->  00:04:38,420
or the wall jack connection.
131

131

00:04:38,420  -->  00:04:41,140
The opposite of an open is considered a short.
132

132

00:04:41,140  -->  00:04:44,040
Now a short indicates that two wires are connected together,
133

133

00:04:44,040  -->  00:04:45,650
somewhere in that connection.
134

134

00:04:45,650  -->  00:04:48,300
Usually, this occurs when a cable is poorly made,
135

135

00:04:48,300  -->  00:04:50,320
or two of the inner twisted pair wires
136

136

00:04:50,320  -->  00:04:51,900
are accidentally touching each other
137

137

00:04:51,900  -->  00:04:54,420
in a single pin of an RJ45 connector.
138

138

00:04:54,420  -->  00:04:56,290
If you're experiencing a short in your connection,
139

139

00:04:56,290  -->  00:04:58,570
you should rewire the RJ45 connection
140

140

00:04:58,570  -->  00:04:59,570
at the end of the cable,
141

141

00:04:59,570  -->  00:05:01,940
as this is usually going to be the source of your problem.
142

142

00:05:01,940  -->  00:05:03,170
If this doesn't fix it,
143

143

00:05:03,170  -->  00:05:05,490
then you need to physically examine the entire cable
144

144

00:05:05,490  -->  00:05:06,470
to see if it's been damaged
145

145

00:05:06,470  -->  00:05:08,480
somewhere in the middle of that cable run.
146

146

00:05:08,480  -->  00:05:10,660
Alternatively, you can simply replace the cable
147

147

00:05:10,660  -->  00:05:11,780
with a known good cable,
148

148

00:05:11,780  -->  00:05:13,660
and this can also solve your issue.
149

149

00:05:13,660  -->  00:05:15,660
If you need to test for incorrect pinouts,
150

150

00:05:15,660  -->  00:05:19,120
opens, and shorts, a good cable tester, a cable certifier,
151

151

00:05:19,120  -->  00:05:22,550
or a wire mapping tool will be the key to your success.
152

152

00:05:22,550  -->  00:05:24,190
If you're testing for a bad port,
153

153

00:05:24,190  -->  00:05:26,510
then a loopback adaptor or a loopback plug
154

154

00:05:26,510  -->  00:05:28,060
is going to be the tool to use.
155

155

00:05:28,060  -->  00:05:29,560
Remember, for the exam,
156

156

00:05:29,560  -->  00:05:30,600
it's important to understand
157

157

00:05:30,600  -->  00:05:32,140
which tool you might need to use
158

158

00:05:32,140  -->  00:05:34,740
to troubleshoot different cable connectivity issues.
159

159

00:05:35,880  -->  00:05:38,052
(electric buzz)